Website review
This review may include AI-generated content and is not individually verified. Domain, certificate and other facts come from the observed data on this page.
What is DANNALAB?
DANNALAB is a contract testing laboratory specializing in X-ray analytical methods for the pharmaceutical and biopharmaceutical industry. Its core services are XRPD (X-ray powder diffraction) and SAXS (small-angle X-ray scattering), delivered under cGMP conditions with regulatory-ready documentation. In practical terms, it is the lab a pharma company turns to when it needs solid-state or structural data that will stand up in a filing, a batch release, or a patent dispute.
What it actually does
The work splits along two method lines, which map to different drug types:
- XRPD for small molecules — polymorphism, crystallinity, and identity of APIs and formulations. Uses include method development and validation, limit-of-detection work, batch release packages with QA-approved certificates of analysis, and EU import testing (which requires GMP testing in an EU laboratory under Directive 2001/83/EC).
- SAXS for biologics and delivery systems — higher-order structure of proteins, peptides, and antibodies in native solution; biosimilar comparability; aggregation and oligomerisation; and the internal structure of liposomes, lipid nanoparticles, nanoemulsions, and other carriers. It also covers mRNA-LNP assembly characterization.
- Peptide CMC — a combined portfolio spanning solution-state aggregation and oligomerisation, lipid-carrier characterization by SAXS/WAXS, and solid-state questions such as amorphicity, crystallinity, and salt forms.
- Medical devices and materials — surface and coating analysis, including XRR (X-ray reflectivity).
The site also advertises patent support: comparing measured XRPD/SAXS data against patent claims and specifications.
Who it suits
A formulation scientist who needs to show that an API hasn't converted to an unwanted polymorph before release, or a biologics team that needs comparability evidence for a biosimilar, is the typical user. The stated cGMP accreditation (since 2014), 21 CFR Part 11 data handling, and references to USP <941> and Ph.Eur <2.9.33> signal that the output is meant for regulators, not just internal R&D. Advertised turnaround of 24–48 hours is aimed at teams facing release deadlines.
Trade-offs to weigh
DANNALAB is a specialist, not a general analytical CRO. That focus is an advantage for X-ray work — method validation, traceable data, and audit-ready documentation are the hard parts — but if your project also needs, say, mass spec, dissolution, or microbiological testing, you will be coordinating several vendors. Turnaround claims are also worth confirming against your specific method, since validated methods and stability studies rarely move at the same speed as routine release testing.
Next step
Before requesting a quote, write a one-page scope: the question you need answered (identity, polymorph screen, comparability, or patent comparison), the sample matrix, the regulatory context (which market, which filing), and your deadline. Send that scope and ask explicitly whether the method you need is already validated or requires development — that single answer usually determines both timeline and cost more than anything else. For independent background on the techniques, the official sites of USP and EDQM publish the general chapters referenced in the documentation.
Which XRPD or SAXS service should I choose for my small-molecule, biopharmaceutical, or peptide program?
Choose by the question your data must answer, not by molecule type alone. DANNALAB organizes its services around application areas, and the right entry point depends on whether you need solid-state identity and form control, solution-state structure, or a mix of both.
Quick selection guide
| If your program is… | Start with | Because |
|---|---|---|
| A small-molecule API or formulation | XRPD | It addresses polymorphism, crystallinity and identity, and supports method development, validation and batch release |
| A protein, antibody or biosimilar | SAXS | It captures higher-order structure in native solution, plus aggregation and comparability work |
| A peptide therapeutic | XRPD and SAXS together | Solid-state form work (amorphicity, polymorphs, salts) and solution-state aggregation or lipid-carrier structure are usually separate questions |
| An LNP, liposome or nanoemulsion | SAXS | It characterizes carrier structure, size distribution and internal organization |
Concrete scenarios
- You are releasing batches of a crystalline small-molecule drug. XRPD fits: the site lists QA-approved CoAs, batch-release support and 24–48 hour turnaround availability, with validation and LOD/LOQ work (0.17–0.5% wt) for quantitative methods.
- You are developing a biosimilar. SAXS in native solution is the more direct fit for comparability and aggregation assessment; XRPD would not answer a higher-order-structure question.
- Your peptide has both a salt-form question and an aggregation question. Plan two workstreams from the start. Combining them under one quality system reduces handoff friction, but they are different methods with different sample requirements.
- You are importing pharmaceuticals into the EU. The site notes that EU import requires GMP testing in an EU laboratory under Directive 2001/83/EC; confirm your specific testing scope against that requirement before commissioning work.
Decision criteria
- Define the regulatory purpose first. Batch release, stability and patent comparison each need different documentation depth. Ask for a technical quote that states the method, validation status and CoA format.
- Check method status. Some SAXS methods are described as cGMP-documented "for selected methods," so confirm your exact assay is covered rather than assumed.
- Match turnaround to your timeline. The advertised 24–48 hours is availability, not a guarantee for every method; validation or feasibility work will take longer.
- Ask what the data will be compared against. For patent or specification work, the site offers technical analysis of XRPD/SAXS data versus claims; supply the claims early so the method is designed for that comparison.
A useful next step is to write a one-paragraph statement of your decision question (form, structure, comparability or release) and send it with your sample matrix and required documentation level when requesting a quote. If you also need complementary techniques outside X-ray characterization, such as mass spectrometry or chromatography, compare specialist providers directly—for example Website Name only if you have confirmed its official domain.
How do I get a technical quote or price list for XRPD and SAXS testing?
Request a technical quote or price list through DANNALAB's quote request on DANNALAB. The site presents itself as a cGMP-compliant XRPD and SAXS testing lab for pharmaceutical CMC, and its homepage offers a "Request a Technical Quote or Price List" path rather than posting prices openly. Expect a scoped quote: the page emphasizes method development and validation, batch release, stability studies, and patent analysis, so the lab will likely need your sample type and purpose before pricing.
What to include in your request
A complete request shortens back-and-forth:
- Technique and application: XRPD for polymorphism, crystallinity, or identity of small-molecule APIs; SAXS for proteins, peptides, antibodies, liposomes, LNPs, or nanoparticles.
- Purpose: development, batch release, stability study, biosimilar comparability, or patent comparison.
- Sample details: matrix, approximate number of samples, and whether the material is potent, unstable, or lipid-based.
- Documentation needs: QA-approved CoA, ICH-compliant validation, or data suited to 21 CFR Part 11 and USP <941>/Ph.Eur <2.9.33> expectations.
- Timeline: the site advertises 24–48 h turnaround as available, so state whether you need that expedited option.
Choosing between a quote and a price list
A price list suits routine, repeat testing where methods already exist. A technical quote fits method development, validation with LOD/LOQ determination, or patent analysis, where scope drives cost. For a first engagement, ask for both: a list price for a defined assay and a scoped quote for your actual samples, then compare what documentation and turnaround each includes.
What documentation and accreditations (cGMP, 21 CFR Part 11, QA-approved CoA) come with DANNALAB's test results?
DANNALAB states that its XRPD and SAXS testing is delivered with regulatory-ready documentation rather than data alone. According to the page, results come with a QA-approved Certificate of Analysis (CoA) that is batch-release ready, and the laboratory describes itself as cGMP accredited since 2014, working to USP <941> and Ph.Eur <2.9.33> and with 21 CFR Part 11 compliance for traceable data. For method work, it also cites ICH-compliant validation and LOD/LOQ determination.
What each item means in practice
- cGMP accreditation: The lab operates under pharmaceutical good-manufacturing-practice expectations, which matters when the data feed a regulatory submission or a release decision rather than internal research.
- 21 CFR Part 11: Points to controlled electronic records and audit trails, so the data package is intended to withstand scrutiny in an FDA-regulated filing.
- QA-approved CoA: A quality-assured certificate suitable for batch release, meaning a QA function has signed off on the result, not just the analyst.
- Pharmacopoeial methods (USP <941>, Ph.Eur <2.9.33>): X-ray diffraction methods aligned to recognised compendial standards, useful when a specification references them.
- Traceable data: Raw and processed data that can be followed back to the measurement, which is what auditors and patent reviewers typically ask for.
A practical scenario
If you are releasing an imported batch into the EU, the documentation bundle is the deciding factor: a QA-approved CoA plus Part 11-compliant records lets your own QA accept the result without re-testing. If you are instead comparing a biosimilar by SAXS, the relevant question is whether the higher-order-structure method itself was validated under ICH and documented to that standard, so ask for the validation report alongside the data.
What to confirm before relying on it
The page notes cGMP documentation is available "for selected methods," so documentation depth can vary by service. Before commissioning work, ask which specific methods carry the full CoA and Part 11 package, request a sample CoA and validation summary, and confirm the accreditation scope covers the technique you need. A useful next step is to request a technical quote that lists the documentation deliverables explicitly.
How fast can DANNALAB deliver XRPD or SAXS results for batch release or stability studies?
DANNALAB advertises 24–48 hour turnaround available for its XRPD and SAXS testing, with QA-approved certificates of analysis described as batch-release ready. That is the fastest figure the site states; it is presented as an option rather than a guaranteed standard time for every project.
What affects the real timeline
The 24–48 hour window most plausibly applies to routine, already-validated measurements — for example a batch-release XRPD identity or crystallinity check on a known API using an established method. Projects that need method development or validation first, such as ICH-compliant validation with LOD/LOQ determination, will take longer because the method work precedes the sample run. Similarly, stability studies usually mean a series of time points rather than a single measurement, so the practical question is how quickly each pull-point is reported, not the total study duration.
A practical way to plan
If you are a CMC or QC lead facing a release deadline, ask for a written quote that separates three things: method status (existing validated method versus new development), the number of samples and time points, and the committed reporting date for the CoA. Treat the 24–48 hour figure as the best case for validated, release-type work and confirm it in writing for your specific assay.
For comparison when scoping alternatives, contract labs such as Eurofins and SGS also publish pharmaceutical X-ray diffraction services; compare their stated method-validation lead times against DANNALAB's fast-turnaround claim before deciding.
Can DANNALAB's XRPD and SAXS data support pharmaceutical patent analysis or EU import testing requirements?
Yes. DANNALAB's XRPD and SAXS services explicitly cover both areas.
Pharmaceutical patent analysis
The site lists a dedicated "Pharmaceutical Patents" application: technical analysis of XRPD/SAXS data against patent claims and specifications. In practice, this is useful when you need to check whether a polymorph or crystalline form in a product falls within a claimed form, or when comparing measured diffraction patterns to forms described in a patent. XRPD is the natural tool for crystalline-form and polymorph comparisons; SAXS adds nanostructural evidence for biologics, liposomes and similar systems. The value depends on documentation quality, so confirm that reports include raw patterns, method parameters and traceable data (the site cites 21 CFR Part 11 traceable data), since those are what make results defensible in a patent dispute.
EU import testing
The site states that pharmaceuticals imported into the EU require GMP testing in an EU laboratory under Directive 2001/83/EC, and positions its EU-located, cGMP-accredited testing (since 2014, referencing USP <941> and Ph.Eur <2.9.33>) as suitable for this. XRPD release testing with a QA-approved CoA and 24–48 h turnaround is offered for batch release and QC packages.
Practical next step
Match the request to the evidence type before quoting: for a patent question, ask for method details and how measured data will be compared to specific claims; for EU import release, confirm the CoA format, accreditation scope and whether your product's test fits a validated XRPD method. For broader context on EU GMP expectations, see European Medicines Agency and USP.
User reviews (0)